Flame Detection Infrared Sensor - LDF001

Single Channel
TO-39 Housing
Switching Output

Technical parameters:

Technical parameters

Symbol

Typical value

Unit

Window size


Ф5.5

mm

Element size

As

Ф2.5

mm

Field of View

FOV

>110

°

Detection Distance (Alcohol fire 0.1m2)

L

>30

m

Operating Temperature

T

-40—+80

No.

Pin

Function

Parameters

1

OEN

Output Enable

High level (>1.1V) is effective, low level (<0.9V) keeps output low

2

VSS

GND


3

VDD

Power Supply 3.3V

Input current at low level is 9.5uA

4

REL

Output

Output high level when there is response

5

ONTIME

Delay Control

ONTIME optional voltage:1/64 Vdd、3/64 Vdd、……、31/64 Vdd etc. 16 gear voltage, delay time ranges from 1.8 seconds to 1 hour

6

SENS

Sensitivity Control

SENS optional voltage:1/128 Vdd、3/128 Vdd、……、63/128 Vdd etc. 32 level voltage, detection distance is adjustable from tens of meters to centimeters


Dimensions (unit: mm)

1730173732578.png


Working principle:

1730173773475.png

Typical Filters parameters are shown in the below figure, other parameters can be customized according to specific requirements of customers.

CWL

4400nm

3800nm

5300nm

HPB

450nm

140nm

180nm

Detector type

LDF001-I-01

LDF001-H-01

LDF001-D-01


Test circuit: