GS136 VOC Air quality sensor

Detecting gas: formaldehyde, benzene, carbon monoxide, natural gas, hydrogen, alcohol, cigarette smoke, etc.
Test range: 0-100ppm (alcohol) 0-10ppm (formaldehyde) 0-10000ppm (natural gas) 0-4000ppm (hydrogen) 0-1000ppm (carbon monoxide)
Detection distance: When the air is polluted, the sensor can sense the degree of air pollution
Installation: air purifier, air conditioner, fresh air system, air quality detector, car purifier.

Key information:

The VOC type air quality (odor) sensor has the advantages of high sensitivity, low cost, long life, low power consumption, etc. It is a broad-spectrum Gas Sensor with high sensitivity to many trace amounts of reducing gases (or micro-toxic gas molecules), which include, among other types of gas molecules, ammonia, hydrogen, alcohols, carbon monoxide, methane, propane, glycol, styrene, propylene glycol, phenol, toluene, ethylbenzene, and xylene, Formaldehyde and other organic volatile gases, cigarettes, wood, paper burning smoke, oil smoke, etc.       

GS-VOC-type air quality (odor) sensor is made of nano-sized SnO2 powder and appropriate amount of catalyst doped and sintered. The conductance of the sensor rises when trace amounts of reducing pollutant gases are present in the air. The amount of change in conductance increases with the concentration of the pollutant gas. Through the size of the conductivity change, the sensor can sense the degree of air pollution. For example, the sensor can produce a change in conductance when second-hand smoke or molecules evaporated from cosmetics are present in the room. Using this sensitive characteristic of the sensor, and then through a simple microcontroller control, it can realize intelligent start exhaust ventilation equipment, so as to achieve the effect of intelligent purification of indoor air.


Features:

Low power consumption

Long life span

Low cost

Small size

High sensitivity to low concentrations of pollutant gases


Key parameters:

Model No.

GS136

Sensor Type

Semiconductor

Standard Encapsulation

        Metal TO-05

Detection Gas

Hydrogen, alcohol, smoke, etc.

Concentration

20-200ppm alcohol,

0-10ppm formaldehyde (HCHO)

0-20ppm Natural gas

0-4000ppm Hydrogen

 

 

Circuit

Loop Voltage

Vc

5.0V±0.1V DC; Ps15mW

Heater Voltage

VH

5.0V±0.1V AC or DC

Load Resistance

RL

Adjustable; Ps15mW

 

 

 

 

 

Character

Heater Resistance

RH

85Ω±10ΩRoom Tem.

Heater consumption

PH

260mW±10mW

Heater current

IH

        55mA±5mA

Sensitivity

S

            >0.5V

Slope

α

≤0.6(R300ppm/R50ppm Alcohol)

 

 

Condition

Tem. , Humidity

20±2℃;65%±5%RH

Preheat time

Over 24 hours

Response time

30s


Configuration (Unit:mm, tolerance:±0.2mm) :